Demonstrating the Feasibility of Using Forearm Electromyography for Muscle-Computer Interfaces

 

Scott Saponas

University of Washington

Desney Tan

Microsoft Research

Dan Morris

Microsoft Research

Ravin Balakrishnan

University of Toronto

We explore the feasibility of muscle-computer interfaces (muCIs): an interaction methodology that directly senses and decodes human muscular activity rather than relying on physical device actuation or user actions that are externally visible or audible. As a first step towards realizing the muCI concept, we conducted an experiment to explore the potential of exploiting muscular sensing and processing technologies for muCIs. We present results demonstrating accurate gesture classification with an off-the-shelf elec-tromyography (EMG) device. Specifically, using 10 sensors worn in a narrow band around the upper forearm, we were able to differentiate position and pressure of finger presses, as well as classify tapping and lifting gestures across all five fingers. We conclude with discussion of the implications of our results for future muCI designs.

Our CHI 2008 paper: [ pdf ]

Saponas S, Tan D, Morris D, Balakrishnan R. Demonstrating the Feasibility of Using Forearm Electromyography for Muscle-Computer Interfaces. Proceedings of ACM CHI 2008.